Product Description
Part Number: EJA110E-JMS5G-919DB/X2/D4/M01/T12/KU22/HART5
Model: EJA110E Differential Pressure Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months
EJA110E features include:
- 0.055% Accuracy (0.04% Accuracy optional)
- 0.1% Stability per 10 years
- 90 ms Response Time
- Exida and TUV SIL 2 / SIL3 Certified
- MWP 2,300 psi (MWP 3,600 psi option)
- Local Parameter Setting (LPS)
Model and Suffix Codes
| Model | EJA110E | Differential pressure transmitter |
| Output signal | -J | 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)(1) |
| Measurement span (capsule) | M | 1 to 100 kPa (4 to 400 inH2O) |
| Wetted parts material(2) | S# | Cover flange and process connector: ASTM CF-8M(3) |
| Process connections | *5 | without process connector (1/4 NPT female on the cover flanges) |
| Bolts and nuts material | G | 316L SST |
| Installation | *-9 | Horizontal piping and left side high pressure |
| Amplifier housing | 1 | Cast aluminum alloy |
| Electrical connection | 9 | M20 female, two electrical connections and a blind plug(4) |
| Integral indicator | D | Digital indicator(5) |
| Mounting bracket | *B | 304 SST 2-inch pipe mounting, flat type (for horizontal piping) |
| Painting | /X2 | Coating change: Coating change(6)(7) |
| Calibration units(8) | /D4 | M calibration (kgf/cm2 unit) |
| Material certificate(9) | /M01 | Cover flange(10) |
| Pressure test/Leak test certificate(11) | /T12 | Test Pressure: 16 MPa(2300 psi) Nitrogen(N2) Ga(12) |
| ATEX | /KU22 | Combined KF22, KS21 and ATEX Intrinsically safe Ex ic(13)(14) [ATEX Intrinsically safe Ex ic] Applicable Standard: EN 60079-0:2012, EN 60079-11:2012 II 3G Ex ic IIC T4 Gc, Amb. Temp.: ?C30 to 60??C (?C22 to 140??F)(15) Ui=30 V, Ci=27.6 nF, Li=0 ??H |
| /HART5 |
The ??*?? marks indicate the most typical selection for each specification.
- HART 5 or HART 7 is selectable. Specify upon ordering
- Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user??s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150??C [302??F] or above). Contact Yokogawa for detailed information of the wetted parts material. - Cast version of 316 SST. Equivalent to SCS14A.
- Material of a blind plug is aluminum alloy or 304 SST.
- Not applicable for output signal code G.
- Not applicable for amplifier housing code 2 and 3.
- Not applicable with color change option.
- The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.
- Material traceability certification, per EN 10204 3.1B.
- Applicable for process connections codes 0 and 5.
- The unit on the certificate is always Pa unit regardless of selection of option code D1, D3 or D4
- Pure nitrogen gas is used for oil-prohibited use (option codes K1, K2, K5, and K6).
- Applicable for Electrical connection code 2, 4, 7, 9, C and D.
- Not applicable for output signal code Q.
- Lower limit of ambient temperature is ?C15??C (5??F) when option code HE is specified.
- Estimated Lead Time: 8 - 9
- Shipping Weight: 5 Kg
Your Can Likes
- YTA710-JA1A2DD New Yokogawa YTA710 Temperature Transmitter
- $1,384.00 $678.00
Save: 51% off
- 2088G3S22A2M5I1 New Rosemount 2088 Gage Pressure Transmitter
- $876.00 $553.00
Save: 37% off
- 3051CD2A02B1BH2B1M4DF New Rosemount 3051C Coplanar Pressure Transmitter
- $979.00 $617.00
Save: 37% off
- 3051S1TG2A2A11A1AB4M5 New Rosemount 3051S Scalable Pressure Transmitter
- $1,092.00 $689.00
Save: 37% off