Product Description
Part Number: EJA530E-JBS7N-019DN
Model: EJA530E In-Line Mount Gauge Pressure Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months
Overview
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.
EJA530E's standard features include:
- ??0.055% Accuracy (0.04% Accuracy optional)
- ??0.1% Stability per 10 years
- 90 ms Response Time
- Exida and TUV SIL2/SIL3 Certified
- Local Parameter Setting (LPS)
Specifications
- Measurement Types
Primary Variable: Gauge Pressure - Reference Accuracy
Primary Variable:
??0.055% of Span
??0.04% of Span (/HAC option) - Stability (All Normal Operating Conditions)
Primary Variable: ??0.1% of URL per 10 years - Response Time
Primary Variable: 90 msec - Rangeability:
Primary Variable:
A, B and C Capsules: 20:1
D Capsules: 10:1
Model and Suffix Codes
| Model | EJA530E | Gauge pressure transmitter |
| Output signal | -J | 4 to 20 mA DC Output with digital communication (HART 5/HART 7 protocol)(1) |
| Measurement span (capsule) | B | 0.1 to 2 MPa (14.5 to 290 psi) |
| Wetted parts material(2) | S | Process connector: 316L SST# Diaphragm: Hastelloy C-276(3)# Others: 316L SST# |
| Process connection | 7 | 1/2 NPT male |
| N | Always N | |
| -0 | Always 0 | |
| Amplifier housing | ?1 | Cast aluminum alloy |
| Electrical connection | 9 | M20 female, two electrical connections with a blind plug(4) |
| Integral indicator | D | Digital indicator(5) |
| Mounting bracket | N | None |
The ????? marks indicates the most typical selection for each specification.
- HART 5 or HART 7 is selectable. Specify upon ordering.
- Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user??s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150??C [302??F] or above). Contact Yokogawa for detailed information of the wetted parts material. - Hastelloy C-276 or ASTM N10276.
- Material of a blind plug is aluminum alloy or 304 SST.
- Not applicable for output signal code G.
The ??#??marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.
- Estimated Lead Time: 6 - 8
- Shipping Weight: 8 Kg
Your Can Likes
- YTA710-JA1A4DD/KU2 New Yokogawa YTA710 Temperature Transmitter