Product Description
Part Number: YTA610-JA1A4DD/A/SU2/C2/P2
Model: YTA610 Temperature Transmitter
Manufacturer: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months
Ordering Information
| Model | YTA610 | Temperature Transmitter |
| Output Signal | -J | 4 to 20 mA DC with digital communication HART protocol |
| A | Always A (Global) | |
| Sensor input | 1 | Single |
| Housing code | A | Aluminum |
| Electrical connection | 4 | M20 female |
| Integral indicator | D | Digital indicator with Local Operating Switch |
| Mounting bracket | D | SUS304 stainless steel 2-inch vertical pipe mounting bracket |
| Lighting protector1 | /A | Allowable current: Max. 6000A(8??20??s), repeating 1000A(8??20??s), 100 times |
| IECEx | /SU2 | 4-20mA: [Intrinsically safe ia, ic pproval] Applicable Standard: IEC 60079-0, IEC 60079-11 Certificate No. IECEx FMG 16.0014X Ex ia IIC T5??T4 Ga Ex ic IIC T5...T4 Gc Ex ia [ia Da] IIIC T135??C Db Ambient Temperature: ?C40 to +70??C for T4 (Ex ia), ?C40 to +50??C for T5 (Ex ia), ?C30 to +70??C for IIIC (Ex ia), ?C30 to +70??C for T4 (Ex ic), ?C30 to +50??C for T5 (Ex ic) Enclosure: IP66/IP67 Over voltage category: I Electrical parameters (Ex ia) Supply/Output circuit: Terminal: +, ?C Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH Sensor circuit: Terminals: 1, 2, 3, 4, 5 Uo=6V, Io=90mA, Po=135mW, Co=10??F, Lo=3.9mH Electrical parameters (Ex ic) Supply/Output circuit: Terminal: +, ?C Ui=30V, Ci=22nF, Li=0mH Sensor circuit: Terminals: 1, 2, 3, 4, 5 Uo=6V, Io=90mA, Po=135mW, Co=10??F, Lo=3.9mH Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A) [Flameproof and Dust Ignition Proof Approval] Applicable standard: IEC 60079-0, IEC 60079-1, IEC 60079-31 Certificate: IECEx KEM 07.0044X Ex db IIC T6/T5 Gb, Ex tb IIIC T70??C/T90??C Db Ambient Temperature for Gas Atmospheres: ?C40 to 75??C (?C40 to 167??F) for T6, ?C40 to 80??C (?C40 to 176??F) for T5 Ambient Temperature for Dust Atmospheres: ?C30 to 65??C (?C22 to 149??F) for T70??C, ?C30 to 80??C (?C22 to 176??F) for T90??C Enclosure: IP66/IP67 Electrical Connection: 1/2 NPT female and M20 female2 |
| NAMUR NE43 compliant3 | /C2 | Output signal limits:
3.8 mA to 20.5 mA Failure alarm down-scale: output status at CPU failure and hardware error is ?C5%, 3.2 mA or less. Sensor burnout is also set to Low: ?C2.5%, 3.6 mA DC. |
| Painting4,5 | /P2 | Color and coating change
Amplifier cover only6 Color: Munsell code 7.5BG4/1.5, Jade green Coating: High anti-corrosion coating |
- Lightning protector (surge absorber) can be remove from, or added to the equipment.
- Applicable for Electrical Connection Code 2 and 4.
- Not applicable for Fieldbus type.
- Not applicable for Stainless housing.
- The combination of X2 and P? is not possible.
- Except for Amplifier and terminal cover, color and coating are general specification.
- Estimated Lead Time: 25
- Shipping Weight: 5 Kg
Your Can Likes
- 266HRHPRRA7LSB7 New ABB 266HRH Gauge Pressure Transmitter
- $1,490.00 $762.00
Save: 49% off
- 3051CG4A22A2AE5 New Rosemount Series 3051 Gauge Pressure Transmitter
- $965.00 $609.00
Save: 37% off
- EJA118W-FMSA1DA-AA07-92DA/D3 New Yokogawa EJA118W Diaphragm Sealed Differential Pressure Transmitter
- $3,324.00 $1,629.00
Save: 51% off
- 3051CD1A02A1BH2HR5 New Rosemount 3051C Coplanar Pressure Transmitter
- $1,217.00 $596.00
Save: 51% off