Product Description
Part Number: YTA610-JA1A4DN/KU2/C2
Model: YTA610 Temperature Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months
Model and Suffix Codes
| Model | YTA610 | YTA610 Temperature Transmitter |
| Output signal | -J | 4 t0 20 mA DC with digital communication HART 7 protocol |
| A | Always A | |
| Sensor input | 1 | Single |
| Housing code | A | Aluminum |
| Electrical connection | 4 | M20 female |
| Integral indicator | D | Digital indicator with Local Operating Switch |
| Mounting bracket | N | None |
| ATEX | /KU2 | 4-20mA: [Intrinsically safe approval] Applicable Standard: EN 60079-0: 2012+A11:2013, EN 60079-11: 2012 Certificate No. FM16ATEX0019X II 1 G Ex ia IIC T5...T4 Ga II 2 (1) D Ex ia [ia Da] IIIC T135??C Db Ambient Temperature: ?C40 to +70??C for T4, ?C40 to +50??C for T5, ?C30 to +70??C for IIIC Enclosure: IP66/IP67 Electrical parameters: Supply/Output circuit: Terminals: +, ?C Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH Sensor circuit: Terminals: 1, 2, 3, 4, 5 Uo=6V, Io=90mA, Po=135mW, Co=10??F, Lo=3.9mH Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A) [Intrinsically safe ic] Applicable Standard: EN IEC 60079-0, EN 60079-11 Certificate: Not Applicable as per Annex VIII to ATEX 2014/34/EU II 3 G Ex ic IIC T5...T4 Gc Ambient Temperature: ?C30 to +70??C for T4, ?C30 to +50??C for T5 Enclosure: IP66/IP67 Overvoltage category: I Electrical parameters: Supply/Output circuit: Terminals: +, ?C Ui=30V, Ci=22nF, Li=0mH Sensor circuit: Terminals: 1, 2, 3, 4, 5 Uo=6V, Io=90mA, Po=135mW, Co=10??F, Lo=3.9mH Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A) [Flameproof and Dust Ignition Proof Approval] Applicable Standard: EN IEC 60079-0, EN 60079-1, EN 60079-31 Certificate: KEMA 07ATEX0130X II 2 G Ex db IIC T6/T5 Gb, II 2 D Ex tb IIIC T70??C/T90??C Db Ambient Temperature for Gas Atmospheres: ?C40 to 75??C for T6, ?C40 to 80??C for T5 Ambient Temperature for Dust Atmospheres: ?C30 to 65??C for T70??C, ?C30 to 80??C for T90??C Enclosure: IP66/IP67 Electrical Connection: 1/2 NPT female and M20 female(1) |
| NAMUR NE43 compliant(2) | /C2 | Output signal limits: 3.8 mA to 20.5 mA Failure alarm down-scale: output status at CPU failure and hardware error is ?C5%, 3.2 mA or less. Sensor burnout is also set to Low: ?C2.5%, 3.6 mA DC. |
- Applicable for Electrical Connection Code 2 and 4.
- Not applicable for Fieldbus type.
- Estimated Lead Time: 6 - 8
- Shipping Weight: 5 Kg
Your Can Likes
- New Foxboro D0179CA Temperature Transmitter Module - Discontinued
- $870.00 $578.00
Save: 34% off
- EJA210E-JHS4G-912DN-WA13C1SW00-B/D4 New Yokogawa EJA210E Flange Mounted Differential Pressure Transmitter
- $2,091.00 $1,025.00
Save: 51% off
- IDP10-T22D21F-M2L1 New Foxboro IDP10 Pressure Transmitter
- $1,860.00 $911.00
Save: 51% off
- STD730-F1HS4AS-1-A-EFB-16S-A-11A0 New Honeywell STD730 SmartLine Differential Pressure Transmitter
- $3,577.00 $1,753.00
Save: 51% off