Product Description
Part Number: 5301HA1H1N4AM00134CDNAM1P1C1Q4Q8S3XCSW2C1
Model: 5300 Level Transmitter
Manufacturer: Rosemount
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months
Ordering Information
| Model | 5301 | Guided Wave Radar Liquid Level or Interface Transmitter (interface available for fully submerged probe) |
| Signal output | H | 4-20 mA with HART communication (default output from factory is HART 5, add option code HR7 for HART 7) |
| Housing material | A | Polyurethane-covered Aluminum (Aluminum alloy A360, maximum 0.6 percent Cu) |
| Conduit / cable threads | 1 | ? - 14 NPT, 1 plug included |
| Operating temperature and pressure | H(1)(2) | Design and operating temperature: -76 to 752 ??F (-60 to 400 ??C) -15 to 5000 psig (-1 to 345 bar) |
| Material of construction: Process connection / probe | 1 | 316/316L/EN 1.4404 |
| Sealing O-ring material | N(3) | None |
| Probe type | 4A | Description: Rigid Single Lead (8 mm) Process connections: Flange / 1- in.(4), 1?-in., 2- in.(4) Thread / Tri Clamp Probe lengths: Min: 1 ft. 4 in. (0.4 m), Max: 9 ft. 10 in. (3 m) |
| Probe length units | M | Metric (meters, centimeters) |
| Total probe length (feet/m) | 001 | |
| Total probe length (inch/cm) | 34 | |
| Process connection - size / type | CD | 4-in. Class 900, RF (Raised Face Type) |
| Hazardous locations certifications | NA | No Hazardous Locations Certifications |
| Display | M1 | Integral digital display |
| Hydrostatic testing | P1 | Hydrostatic testing, including certificate |
| Factory configuration | C1 | Factory configuration per Configuration Data Sheet |
| Special quality assurance | Q4 | Calibration data certificate |
| Material traceability certification | Q8 | Material traceability certification consistent with ISO10474-3.1:2013 / EN10204-3.1:2004 |
| Centering discs | S3(5) | Description: 3-in. Centering disc Outer diameter: 2.7 in. (68 mm) |
| Assemble/consolidate to chamber | XC | Consolidate to Chamber |
| SW2 | ||
| C1 |
- Requires option None for sealing (no O-ring).
- For applications where a large amount of contamination is present a standard or high pressure seal should be used, if process conditions allow.
- Requires Operating Temperature and Pressure code H, P, or C.
- Only available with Operating Temperature and Pressure code S.
- Available for SST, Alloy C-276, Alloy 400, Alloy 825, and Duplex 2205 probes, type 2A, 4A, 4B, 4S, and 5A. Same disc material as probe material.
- Estimated Lead Time: 8 - 10
- Shipping Weight: 25 Kg
Your Can Likes
- EJA110E-JMS5G-924DB New Yokogawa EJA110E Differential Pressure Transmitter
- $2,154.00 $1,056.00
Save: 51% off
- 3051CD3A02A1BS5I1M5Q4Q8 New Rosemount 3051C Coplanar Pressure Transmitter
- $1,071.00 $676.00
Save: 37% off
- 2051TG3A2B21AB4M5D4Q4 New Rosemount 2051 In-Line Pressure Transmitter
- $966.00 $473.00
Save: 51% off
- EJX118A-FMSCG-919DB-WA12B2HW00-AA23/KS25/D4/N4/M2W/T52 New Yokogawa EJX118A Differential Pressure Transmitter
- $7,096.00 $3,477.00
Save: 51% off




