Product Description
Part Number: LV431756
Model: Circuit breaker Compact NSX250H
Brand: Schneider Electric
Characteristics
Range: Compact
Product name: Compact NSX
Device short name: Compact NSX250H
Product or component type: Circuit breaker
Device application: Motor
Poles description: 3P
Protected poles description: 3t
[In] rated current: 220 A at 65 °C
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Suitability for isolation:
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Utilisation category: Category A
[Icu] rated ultimate short-circuit breaking capacity:
85 kA at 240 V AC 50/60 Hz conforming to UL 508
65 kA at 480 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance level: H 70 kA 415 V AC
Trip unit name: MA
Trip unit technology: Magnetic
Trip unit protection functions: I
Control type: Toggle
Circuit breaker mounting mode: Fixed
Model: Circuit breaker Compact NSX250H
Brand: Schneider Electric
Characteristics
Range: Compact
Product name: Compact NSX
Device short name: Compact NSX250H
Product or component type: Circuit breaker
Device application: Motor
Poles description: 3P
Protected poles description: 3t
[In] rated current: 220 A at 65 °C
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Suitability for isolation:
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Utilisation category: Category A
[Icu] rated ultimate short-circuit breaking capacity:
85 kA at 240 V AC 50/60 Hz conforming to UL 508
65 kA at 480 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance level: H 70 kA 415 V AC
Trip unit name: MA
Trip unit technology: Magnetic
Trip unit protection functions: I
Control type: Toggle
Circuit breaker mounting mode: Fixed
Your Can Likes
- C65N-C10A/2P New Schneider Electric Miniature Circuit Breaker
- $126.00 $62.00
Save: 51% off
- 1SDA068165R1 New ABB XT2H 160 Breaking Part 3p F F
- $1,180.00 $578.00
Save: 51% off
- 3RV1031-4FA10 New Siemens Circuit Breaker
- $439.00 $261.00
Save: 41% off
- NF250-SW 225A 2P New Mitsubishi Circuit Breaker [SAME DAY DELIVERY]
- $279.00 $137.00
Save: 51% off




![NF250-SW 225A 2P New Mitsubishi Circuit Breaker [SAME DAY DELIVERY] NF250-SW 225A 2P New Mitsubishi Circuit Breaker [SAME DAY DELIVERY]](images/Circuit Breaker/qt1_mitsubishi.jpg)