Product Description
Part Number: YTA610-JA1A2NB/FU1
Model: YTA610 Temperature Transmitter
Manufacturer: Yokogawa
Description
The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.
YTA610 features include:
Dual-compartment field-mount housing
Choice of HART 7, or FOUNDATION Fieldbus ITK 6 Protocol
Local Parameter Setting function (Indicator model)
Basic diagnosis
Ordering Information
Model: YTA610 - Temperature Transmitter
Output Signal: J - 4 to 20 mA DC with digital communication HART 7 protocol
A - Always A
Sensor Input: 1 - Single
Housing Code: A - Aluminum
Electrical Connection: 2 - 1/2 NPT female
Integral Indicator: N - None
Mounting Bracket: B - SUS304 stainless steel 2-inch vertical pipe mounting bracket
FM (US): /FU1
Estimated Lead Time: 3 - 7 days
Shipping Weight: 6 Kg
Model: YTA610 Temperature Transmitter
Manufacturer: Yokogawa
Description
The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.
YTA610 features include:
Dual-compartment field-mount housing
Choice of HART 7, or FOUNDATION Fieldbus ITK 6 Protocol
Local Parameter Setting function (Indicator model)
Basic diagnosis
Ordering Information
Model: YTA610 - Temperature Transmitter
Output Signal: J - 4 to 20 mA DC with digital communication HART 7 protocol
A - Always A
Sensor Input: 1 - Single
Housing Code: A - Aluminum
Electrical Connection: 2 - 1/2 NPT female
Integral Indicator: N - None
Mounting Bracket: B - SUS304 stainless steel 2-inch vertical pipe mounting bracket
FM (US): /FU1
Estimated Lead Time: 3 - 7 days
Shipping Weight: 6 Kg
Your Can Likes
- EJA430E-FBS5G-919EB/KS26/M01/T12 New Yokogawa EJA430E Gauge Pressure Transmitter
- $1,783.00 $874.00
Save: 51% off
- EJA120E-JES5G-919DB/NS21/X2/D4/M01/T04 New Yokogawa EJA120E Differential Pressure Transmitter
- $2,750.00 $1,348.00
Save: 51% off
- TTH300-L1-H-BS-D4-M5 New ABB TTH300 Head-Mounted Temperature Transmitter
- $729.00 $434.00
Save: 40% off
- EJA430A-FAS4B-29EA/KS25 New Yokogawa EJA430A Gauge Pressure Transmitter
- $1,644.00 $806.00
Save: 51% off